Type
Operating voltage/load voltage
The following special features apply:
– Permitted tolerance in load voltage
supply for valves (V
Current consumption of the CMPX
– of operating voltage supply for
electronics/sensors (V
– of load voltage supply for valves
(V
)
VAL
Electrical isolation
– between the operating voltage
supply for the electronics/sensors
(V
) and the load voltage
EL/SEN
supply for the valves (V
Power failure bridging time
Axis string
Number of axis strings/number of axes
Max. total length (all cables/tubing)
Design of axis connection
14
)
VAL
)
EL/SEN
)
VAL
CPX-CMPX-C-1-H1
See CPX system manual
P.BE-CPX-SYS-...
20 ... 30 V
typ. 200 mA at 24 V
max. 300 mA
typ. 1 ... 2 A at 24 V
max. 2.5 A
none
10 ms (in systems with the
DGCI a power failure > 1 ms
leads to error E.85)
1/1
30 m
Socket M9, 5-pin
Festo CMPX-C-1-H1-Z6 1112NH English