The "Timer" button is used to set the operating time. The next press of a button increases the operation time which is indicated by
the appropriate indicator light. If the indicator light goes out, it means that the appliance is running continuously.
Use the "Mode" button to set the operating mode of the appliance. Normal mode of operation is possible, where the user enters all
settings manually. Automatic mode, where the appliance automatically selects the operating parameters - the "Auto" indicator light
will come on. Night mode, where the appliance switches off the control panel in addition to the "Sleep" indicator light. This mode
should be set for the night when the appliance is to operate in the same room where people are sleeping.
The "Speed" button is used to set the fan speed. Higher speed increases operation capacity, but also causes more noise.
The "Anion" button starts or stops the air ioniser. When the ioniser is activated, oxygen anions are produced in the appliance,
which can have a positive eff ect on your well-being.
The "Top Speed" button activates the highest fan speed. Pressing this button again will restore the previous fan speed setting.
The "Speed" indicator light shows the graphical representation of the fan speed.
The "PM2.5" indicator light shows the amount of PM2.5 particles in the air in μg/m
The "Temp." indicator light shows the air temperature in the room where the appliance operates.
The "Timer" indicator light shows the set operation time. After the set time has elapsed, the appliance will automatically switch off .
The "Air Quality" indicator light shows the air quality using the illumination colour. Green - good quality, orange - medium quality,
red - bad quality.
The "Remove HCHO" indicator light - function of removal of HCHO compounds (formaldehydes) through air purifi cation. This
function activates on its own once the appliance is switched on and cannot be switched off .
The "Purify" indicator light - air cleaning function. This function activates on its own once the appliance is switched on and cannot
be switched off .
The "Anion" indicator light - illuminates when air ionisation is on.
The "Sleep" indicator light - illuminates when the night mode is on.
The "Remove fi lter" indicator light - illuminates when fi lter replacement is required.
The "Auto" indicator light - illuminates when automatic operation mode is running.

MAINTENANCE, TRANSPORT AND STORAGE

Warning! All maintenance works and transport must be carried out with the appliance's electric power supply disconnected. Pull
the plug out of the power supply socket.
Clean the appliance from outside with a slightly damp cloth and then wipe dry with a dry cloth. Clean the inlet and outlet vents
with a paintbrush or soft bristle brush. The fi lters do not require cleaning, dirty fi lters should be replaced with new ones. The fi lters
cannot be regenerated or cleaned.
If the water tank is installed in the appliance, it must be emptied. In addition to the removable tank, there is a fi xed tank in the
appliance, which must be emptied by pulling water from it using a pump (not included). Water should be removed from the tanks
not less frequently than every three days. Do not keep the water in the tank due to the possibility of growth of microorganisms.
Before refi lling, clean the tank with clean water. Remove any scale, sediments or fi lm which has accumulated on the walls or inside
the tank. Then wipe the tank dry. Pour one tablespoonful of citric acid into the tank and 100 ml of warm water with the temperature
not exceeding 70
C. Mix the acid and leave the solution in the tank for 5 minutes. Then empty the tank, rinse with clean water
O
and leave it open until completely dry.
Never use solvents, acids, or alcohol for cleaning. Clean the base and the lid with a soft, damp cloth. Never immerse the appliance
in water or any other liquid.
Transport the appliance by gripping the handles. Transport in operating position. If transported over longer distances, transport
the appliance in a packaging which protects it from damage. Store the appliance in rooms which protect against dust and moisture
and are well ventilated. It is recommended to store the appliance in its original packaging. Do not place anything on the appliance
during storage.
Caution! During long-term storage, the fi lters wear out, although at a lower rate than during use. For long-term storage, it is rec-
ommended to pack the fi lters in airtight plastic bags. Remove the fi lters from the bags before use.

TECHNICAL DATA

Parameter
Catalogue No.
Rated voltage
Rated frequency
Rated power
Protection class
Maximum particulate removal capacity
Operation area
Weight
Noise level – sound pressure L
wP
O R I G I N A L
GB
3
.
Unit
[V~]
[Hz]
[W]
[m
/h]
3
[m
2
]
[kg]
[dB(A)]
I N S T R U C T I O N S
Value
66930
220 - 240
50/60
40
II
220
20 - 35
4.1
<70
11