English
Easy steam
i
Mould:
use short lance (12-13*) and the circular bru-
sh (15*) covered with the cloth at least 2 or 3
times and fi xed with an elastic to the lance.
Add some drops of bleach onto the cloth.
Minimum steam.
Wax:
Floors can be waxed with the covered mul-
tifunction brush (cloth). Minimum steam. It is
recommended to use little wax and put it on
the cloth already heated by the steam and
pass more than 2-3 times.
Scale on steel parts:
Moisten the surface with vinegar.Use the
short lance (13*) with the circular brush. Max.
steam. Pay attention as vinegar, used repea-
tedly and left in contact with steel for a long
time, can dull the surface.
INTRODUCTION
The temperature of steam coming out of the
different accessories can have different va-
lues.
The max. temperature of steam in the lance
is approx. 130° while at a distance of 20 cm is
approx. 50°C.
The temperature of steam with covered bru-
shes (brushes with cloth) has 3 values:
- minimum steam 60-70° C
- medium steam 80-90° C
- maximum steam 90-100° C
* = particular in fi g. 1 page 30