6. ELECTRICAL DIAGRAM
Switch positions
POSITION "0": The turbine starts at SILENT SPEED
(ECO) automatically when the appliance has a fire,
and the cast iron reaches 50ºC (where the ther-
mostat is located).
The turbine stops when the flame has extin-
guished inside the Stove, and the temperature of
the cast iron drops below 50°C.
This position is RECOMMENDED when the user
wants the turbine to stop once the Stove is cold.
POSITION "1": The turbine starts at a SILENT
SPEED (ECO) if operated MANUALLY via the
switch and the appliance has not yet reached the
temperature of 50°C. Once the appliance has
reached 50°C, the turbine automatically increases
the speed to the MINIMUM SPEED. In this posi-
tion, the turbine will not stop even if the flame in
the firebox has been extinguished and the tem-
perature of the cast iron is below 50ºC. When the
appliance is cooling down in this position, the tur-
bine automatically reduces the speed from MINI-
MUM SPEED to SILENT SPEED (ECO) once the ap-
pliance drops below 50°C.
POSITION "2": The turbine starts at MAXIMUM
speed MANUALLY.
In this position, the turbine does not stop even if
the flame has gone out, and the temperature of
the cast iron is below 50ºC.
This position is recommended when a quick trans-
fer of heat from the Stove to the room is re-
quired.
DO NOT DISCONNECT THE STOVE FROM THE
POWER SUPPLY
17