CAUTION
Before troubleshooting, disconnect the unit from the
mains. Only a qualified electrician or other competent
person is allowed to carry out work on the appliance that
is not indicated in this user's manual.
Important Abnormal noise during operation (compressor, refrigerant circulation).
Problem
Possible cause
The thermostat is set to the
number "0"
The plug is not connected or
is loose
The device does not
work
The fuse has blown or is
defective
The fuse has blown or is
defective
The temperature is not set
correctly.
The door has been left open
for a long time.
Food is not cold
A large amount of hot food
enough.
has been placed in the
appliance in the last 24
hours.
The device is close to a heat
source.
The appliance is too
The thermostat has been set
cold.
too cold.
14
Solution
Set the thermostat to a different
number to turn the unit on.
Connect the plug.
Check the fuse, replace it if
necessary.
Check the fuse, replace it if
necessary.
Please lower the initial
temperature
Do not open the door for longer
than necessary.
Temporarily set the temperature
to a cooler position.
Please refer to the Installation
Location section.
Turn the thermostat temporarily
to a warmer position.
14
EN
C
A
Useful information
Aperçu de l'appareil
Problem
Possible cause
The appliance is not
horizontal.
The appliance is touching
the wall or other objects.
Unusual noises
A component at the back
of the appliance, such as a
pipe, is touching another
part of the appliance or the
wall.
Water pooling on the
The water drain hole is
floor.
blocked.
The side panel is
The condenser is inside the
warm
panel.
15
15
Solution
Readjust the feet.
Shift the appliance slightly.
If necessary, carefully bend the
component away.
See the Cleaning section.
This is normal.
EN