Inputs and outputs
Description
In0
Configuration of relay AUX2
O10
0=Deactivated
4=Solenoid for Hot Gas
Configuración del relé AUX3
†
o20
0=Desactivado
1=Heat resistor
Configuration of DEF relay
o80
HUMID. relay configuration
o81
Analogue output type (AN. OUT)
o90
0=4-20 mA
o91
P proportional constant of analogue output
o92
I integral constant of analogue output
EP
Exit to level 1
HACCP alarm
Description
h1
Maximum temperature of HACCP alarm
KCP
h2
Maximum permitted time for activation of the HACCP alarm (0=Disabled)
EP
Exit to level 1
Logger (Only with CAMM module)
Description
L1
Log interval
dLg
L2
Delete record and event log
Record start day
l3
3=Thursday 4=Friday
l4
Decimal separator for the .cvs file
EP
Exit to level 1
* According to wizard.
1=Alarm
2=Light
2=Dehumidifier
0=Deactivated 1=Extractor fan
2=Defrost
0=Deactivated
1=Extractor fan
2=Humidifier
1=0-10 V
0=1 min. 1=5 min. 2=15 min. 3=30 min. 4=60 min.
0=No
1=Yes
0=Monday 1=Tuesday 2=Wednesday
5=Saturday 6=Sunday
0=, 1=.
†
It can only be modified using the configuration wizard (In1/2).
23 23
Values Min.
3=Virtual control
Values Min.
ºC/ºF
H.
Values Min.
1662H411 Ed.06