2. Range of use

SPIDO Submersible dirty water pumps are highly efficient electrical pumps for discharging clear or dirty water
containing solids up to the maximum size specified in the technical details. These high-quality products with their
convincing performance data were developed for the multiple purposes involved with draining and pumping
liquids from one place to another.
Typical applications for waste water submersible pumps are: Emptying ponds, tanks, storage tanks, and waste
water pits, as well as emergency drainage in the event of flood or high water.
SPIDO Submersible dirty water pumps are suitable for stationary or temporary installations.
This product was developed for private use, i.e. not for industrial applications or for continuous operation.
The pump is not suitable for use in table-top fountains, aquariums or similar ranges of use. When using the unit in
a pond, please take the required action to ensure that no inhabitants of the pond will be sucked in.
The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. temperature of the liquids to be discharged
stated in the technical data.
A distinctive feature of this pump is that it can briefly operated (max. 4 min.) with liquids with a
temperature up to 95°C (see Technical data)
Inside the pump, lubricants are used which may contaminate the liquids being discharged in
case of any improper operation or damage of the device. The lubricants used are biologically
degradable and non-hazardous to health.

3. Technical Data

Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
Max. delivery height (H
)
max
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature (T
max
Max. short-term temp. of the pumped liquid (T
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Min. self-priming level (A)
2)
Min. suction level (B)
2)
Cut-in level (C)
2)
Cut-out level (D)
Dimensions (L x D x H)
1)
The values were determined with free, unreduced outlet.
2)
The values between brackets refer to the illustrations given at the end of these operating instructions.
If the water temperature is between 50°C and 95°C the device will only work for 4 minutes and then will switch off automatically to allow the
3)
motor to completely cool.
8
1)
)
<4min)
max
2)
ECC PRO 300
230 V ~ 50 Hz
1,200 Watts
IP68
47.80 mm (1½"), male
19,500 l/h
1.05 bar
10.5 m
7 m
40 mm
50 °C
3)
95 °C (max. 4min)
30, evenly distributed
10 m
H07RN-F
~ 10.2 kg
135 mm
55 mm
450 mm
250 mm
17 x 20 x 43 cm
2