Decommissioning - turbionaire REVIGO10 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Water
Overflow while moving the unit.
Leakage
Check if the drain hose is kinked
or bends.
Excessive
Check if the unit is securely
Noise
positioned.
Check if any loose, vibrating parts.
Noise sounds like water flowing.
ERROR
E0
Communication faults between
CODES
main PCB and display PCB.
Ambient temperature sensor
E1
failure
E2
Coil temperature sensor failures.
Condensate water high level
Ft
alarm.

8. DECOMMISSIONING

STORAGE
Long-Term Storage - If you will not be using the unit for an extended period of time (more
than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit
per the following steps:
- Unplug the unit and remove exhaust hose and window kit store with the unit.
- Drain the remaining water from the unit.
- Clean the filter and let the filter dry completely in a shaded area.
- Re-install the filter at its position.
- The unit must be kept in upright position when in storage.
- Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.
ATTENTION:
The evaporator inside the machine has to be dried out before the unit is packed to avoid
component damage and molds. Unplug the unit and place it in a dry open area for days to
dry it out. Another way to dry the unit is turn on the machine, adjust it to low-wind
ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to
keep the inside of the body in a dry state and prevent it from mildewing.
DISPOSAL
Releasing refrigerant into
atmosphere is strictly forbidden!
WARNING
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities. Contact
your local government for information regarding the
collection systems available. If electrical appliances are
disposed of in land¬fills or dumps, hazardous substances
can leak into the groundwater and get into the food chain,
damaging your health and well-being.ry, so as to keep the
inside of the body in a dry state and prevent it from
mildewing.
Empty the water tank before
transport.
Straighten the hose to avoid a trap
existing.
Place the unit on horizontal and
firm ground.
Secure and tight the parts.
Noise comes from flowing
refrigerant. This is normal.
Check the wire harness of the display
PCB for damage.
Check connection or replace it. To
clean or replace the temperature sensor.
Check connection or replace it. To
clean or replace the temperature sensor.
Empty the drain pan by removal the
rubber plug.
15