- When the unit operates in the cooling operation, drying operation, the ambient temperature
sensor senses the evaporator coil temperature is below -1°C, after the compressor will stop
operating for 10 minutes or the coil temperature up to 7℃, the unit restart to cool operating
mode.
- When the unit operates in the drying operation, once the coil temperature sensor senses the
temperature of the evaporator is below 40℃ and the differential temperature between coil
temperature and room temperature is below 19℃ after the compressor operation for
20minutes, the unit start defrosting for 5 minutes and the power indicator blinking. Overload
Protection - In the event of a power loss, to protect the compressor there is a 3-minute delay
until the compressor restarting.
DRAINAGE
Self- evaporating system
The self-evaporating system uses the collected water to cool the condenser coils for
better efficient performance. It is no need to empty the drainage tank in cooling
operation except in drying operation and high humidity conditions. The condensate
water evaporates at the condenser and evacuated through the exhaust hose.
For continuous operation or unattended operating in drying and heating operation,
please connect the attached drain hose to the unit. Condensate water can be
automatically flow into a bucket or drain by gravity.
- Switch off the unit before operating.
- Remove the plug of the water outlet
opening, and keep it in safe area.
- Securely and properly connect the drain
hose and make sure it is not kinked and
clear of obstruction.
- Place the outlet of hose over a drain or
bucket and ensure that water could freely
flow out of the unit.
- Do not submerge the end of hose into
water; otherwise it can cause "Air Lock" in
the hose.
To avoid water spillage:
As the negative pressure of condensate drain pan is large, tilt the drain hose
downward toward the floor. It is appropriate that the degree of inclination should exceed 20
degrees.
Straighten the hose to avoid a trap existing in the hose.

6. CLEANING AND CARE

CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the
efficiency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not
operate the unit without an air filter, or the evaporator may be contaminated.
- Press POWER button to switch off the unit and unplug the power cord.
- Remove the filter mesh from the unit.
- Use a vacuum cleaner to suck dust from the filter.
- Turn the filter over and rinse the air filter under running water. Let the water run through
the filter in the opposite direction of air flow. Set aside and allow the filter to air dry
completely before reinstalling.
Remove the rubber sealing plug
Continuous drain hose
13