Télécharger Imprimer la page

Vimar 02955 Guide Rapide Installateur page 2

Masquer les pouces Voir aussi pour 02955:

Publicité

Les langues disponibles

Les langues disponibles

02955
INSTALLER/USER QUICK GUIDE
Electronic touchscreen timer-thermostat for ambient temperature control (heating and air-
conditioning), locally programmable via dedicated app, class I temperature control device
(contribution 1%) in ON/OFF mode, class IV (contribution 2%) in PID mode, 1 input for
external temperature sensor, 1 programmable multifunction input, 1 RJ9 input for energy
meter, change-over relay output 5(2) A 230 V~, power supply 120-230 V~ 50/60 Hz, RGB
LED backlighting, to be completed with Eikon, Arké or Plana cover plates - 3 modules.
The device, equipped with a capacitive touch screen interface with colour backlighting, is ideal
for controlling heating and air-conditioning systems via relay output C, NC, N/O. It is equipped
with a built-in buzzer, multi-function input for remote control and an input for managing an exter-
nal temperature probe (not supplied). It can also be connected to the energy probe 02960 (not
supplied) for viewing the consumption/production of electrical energy and the corresponding
historical data. Easier programming with a smartphone application, available for iOS, Android
and WindowsPhone. The timer-thermostat is a universal 3-gang device in the Eikon, Arkè and
Plana series.
FEATURES.
• Rated supply voltage: 120-230 V~, 50-60Hz
• Appliances of class II:
• Max power drawn from the grid: 1 VA
• Operating temperature range: 0-40°C (-T40)
• Temp. measurement accuracy (built-in probe): 0.5°C between +15°C and 30°C, 0.8°C at the ends.
• Relay output with clean change-over contacts: 5(2)A 230 V~
• Terminals: L live, N neutral, IN phase-Multi, C relay, NC relay, N/O relay, 2 external temp.
probe (art. 02965.1), RJ9 socket for connecting energy probe (art. 02960)
• Protection class: IP20
• Action type: 1.B.U
• Degree of pollution 2 (normal)
• Rated pulse voltage: 4000 V
• ErP classification (Reg. EU 811/2013): ON/OFF: class I, contribution 1%; PID: class IV,
contribution 2%.
• PROGRAMMABLE VIA SMARTPHONE OR TABLET AFTER DOWNLOADING THE SPE-
CIAL APP FROM THE SITE energy-management.vimar.it/en
MAIN SETTINGS
Tap
and then, using
(blinking icon) and confirm with
AUTO Selecting operating mode
Using
and
select
.
Setting MANUAL operation
Using
and
.
ANTIFREEZE
Select
to set the Antifreeze temperature (to protect the pipes).
Switching OFF
Select OFF and the timer-thermostat will switch off and no longer make any adjustments.
Setting the time and day of the week
Using
and
set the minutes and then the day of the week. The days of the week are represented by 1 to 7.
Selecting heating/air-conditioning
Using
and
select
Setting units of measurement
Using
and
select °C or °F and confirm with
Setting AUTO operation
As soon as you enter the menu, the display shows a flashing dash for the day to which the
current programming refers.
1. Using
and
.
2. Using
and
current time (which is shown on the clock). This temperature, highlighted by the blinking, can
be selected from:
: Away temperature (T away)
: Economy temperature (T economy)
: Comfort temperature (T comfort)
The 3 "dashes" blinking in sequence indicate the time slot that you are setting. The selected
temperature will be applied beginning at the indicated time for all of the next quarter of an hour.
3. Tap
to assign the temperature you have just set to the following fifteen minutes too.
49400544C0 02 1804
and
, select the desired menu
.
or AUTO or
or OFF and confirm with
set the desired temperature and confirm with
set the time, confirm with
and similarly
or
and confirm with
select the day to program and confirm with
select the temperature to be associated with the
4. Using
the day and move forwards or backwards 15 minutes at a time. With
set the desired temperature.
Programming ends when the temperatures have been set for all the hours of the day and the
clock displays the time 23:45. Tap
5. Using
and
: to copy the entire time program for the current day onto the next day.
: to move on to program the next day without making a copy of the day you have just set
: to finish programming.
Tap
to confirm.
When operating in AUTO mode, tap
perature to a value other than the one associated with the current time slot. Confirm with
and you go into TIMED MANUAL mode.
Operating mode selection
1. Using
.
2. Using
and
just set is to be maintained and confirm with
Setting temperatures
At the end of the set time you go back into AUTO mode, the
AUTO reappears.
Using
,
1.
and
: Away temperature (T away)
2.
and
: Economy temperature (T economy)
3.
and
: Comfort temperature (T comfort)
4.
and
: external probe alarm temperature (if fitted and configured)
5.
: temperature differential of the device (only if in OnOff adjustment mode)
6.
and
: thermal delta in remote reduction mode (if enabled)
7.
and
: "antifreeze" mode temperature (only if in "heating" mode)
Setting the buzzer
Using
and
Setting the display colour
Using
and
confirm with
By selecting
you customize the colour (in a range of 360 RGB values) with
and
, and once you reach the desired colour tap on
Setting the password
Using
and
each digit with
Setting the PIN to "000" gives free access to the device (equivalent to not setting the
password).
FOR THE INSTALLER
For further information and for details on all the other timer-thermostat menus please
refer to the installer manual that can be downloaded from the website www.vimar.com.
FOR THE USER
Before using the timer-thermostat please consult the user manual that can be downlo-
aded from the website www.vimar.com. Keep this documentation for future reference.
INSTALLATION RULES.
.
Installation should be carried out by qualified personnel in compliance with the current regula-
tions regarding the installation of electrical equipment in the country where the products are
installed.
.
REGULATORY COMPLIANCE.
LV directive. EMC directive.
Standard EN 60730-2-7, EN 60730-2-9.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be
included with other general waste at the end of its working life. The user must take the worn product to a sorted
waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned
free of charge (without any new purchase obligation) to retailers with a sales area of at least 400 m
measure less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the
used device, or its subsequent recycling, helps avoid the potential negative effects on the environment and
people's health, and encourages the re-use and/or recycling of the construction materials.
and
move respectively between the hours of
to confirm.
select:
and
and
set the desired temperature and confirm with
set the time for which the temperature you have
.
,
,
and confirming with
select ON or OFF and confirm with
select
or
or
or
.
set the digits of the PIN one at a time and confirm
.
36063 Marostica VI - Italy
and
to set the tem-
icon switches off and
set:
.
or
or
and
.
2
, if they
Viale Vicenza, 14
www.vimar.com

Publicité