INSTALLATION MEASURES

To carry out a proper installation of the operator parts as well as
to ensure the best automation performance, the measurement
levels shown in the following table shall be complied with.
Change the gate structure to adapt it to one of the cases in the
table, if necessary.
FIG.2
BRACKETS HEIGHT
Fix the brackets keeping 35 mm between the surfaces in order
tofix the gear-motor horizontally. (FIG.3).
FIG.3
g
- 12 -
g
E [mm]
A [mm]
100
145
110
145
120
140
130
140
140
135
150
130
100°
160
125
170
120
180
115
190
110
200
105
210
105
220
100
100
140
110
140
120
135
130
135
140
125
110°
150
125
160
120
170
115
180
110
190
105
200
100
100
135
110
135
120
135
120°
130
130
140
130
150
125
160
125
100
145
130°
110
140
120
140