Programme Table - Grohe Tectron 37 321 Manuel D'installation

Masquer les pouces Voir aussi pour Tectron 37 321:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10

Programme table

Programme
1
Temporary shutoff*
2
Automatic flushing*
Flush interval
Usage-dependent
Usage-independent
Detection zone
3
Pre-flushing*
4
Intermediate flushing*
Cleaning mode can be activated when temporary shutoff is activated. In cleaning mode, flushing is not triggered
1
*
for 3 minutes, even if an object is detected.
2
Automatic flushing serves to ensure water hygiene in the event of long-term non-utilisation of the fitting. Flushing is initiated
*
after 24 hours (usage-independent) or 24 hours/72 hours after the fitting was last used (usage-dependent).
3
When pre-flushing is active, flushing is initiated 2 seconds after an object is detected.
*
When intermediate flushing is active, flushing is initiated every 2 minutes if an object is continuously detected (max. 14x).
4
*
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• Transformer defective
• Cleaning mode activated
Undesired water
• Sensor system detection zone set too high
flow
Water flowing
• Solenoid valve defective
continuously / flow
volume too high
Flow volume too
• Filter upstream of solenoid valve blocked
low
• Solenoid valve defective
1
2
3
Active
Active
Active
Active
Active
Active
24 h
24 h
24 h
x
x
x
45cm
45cm
45cm
Inactive
Active
Inactive
Active
Active
Active
Remedy
- Open shut-off valves
- Clean or replace filter
- Replace solenoid valve
- Check plug-in connector
- Replace transformer
- Terminate cleaning mode prematurely or wait
3 minutes
- Reduce detection zone using remote control
(special accessory, prod. no.: 36 206)
- Change selected programme, see detection zone
- Replace solenoid valve
- Clean or replace filter
- Replace solenoid valve
4
5
6
Active
Active
Active
Active
Active
Active
24 h
72 h
72 h
x
x
x
55cm
45cm
45cm
Inactive
Active
Inactive
Inactive
Active
Active
7
Inactive
Inactive
-
-
-
45cm
Inactive
Active
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tectron 37 336

Table des Matières