Wood's MRD10 Mode D'emploi page 12

Masquer les pouces Voir aussi pour MRD10:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
Operating Instructions
GB
MAINTENANCE
- Clean the unit with a soft moist cloth. Do
not use solvents or strong cleaners as this
might damage the surface of the unit.
- The cooling coils are best cleaned with a
rag and warm water.
SERVICE
If the dehumidifier requires servicing,
you must first contact your local retai-
ler. Proof of purchase is required for all
warranty claims.
STORAGE
Before storage of the unit, please follow
these steps:
PROBLEM
CAUSE
Dehumidifier does
The power is not connected
not work
Does not dehumidify
The water container is full.
The water container has not been replaced correctly.
The air filter is clogged. The temperature or relative humidity in
the room where the device is operating too low.
The dehumidifier
The room is too large.
works, but reduce
the relative humidity
There are too many sources of humidity.
insufficiently.
There is too much ventilation
If you are having trouble with your dehumidifier, please refer to the trouble shooting. If none of these works,
please contact your retailer for servicing of your dehumidifier.
12
1.
Make sure the water tank is empty.
When the unit is switched on, make
sure the unit work at Ventilation mode
for at least 30 minutes to remove the
water inside the unit.
2.
Collect and bundle the power cord.
3.
Clean the filter.
4.
Store in a clean, dry environment.
Proof of purchase is required for all
warranty claims.
HINTS
When the dehumidifier is used in
extremely damp environments or when
the temperature is below +5˚C, the
dehumidifier may stop working. A large
amount of ice builds up on the cooling
coil. Turn off the dehumidifier and place it
a little above floor level so that the ice will
melt away.
Sometimes it may be useful to use a frost
guard or heater fan to make sure that the
temperature does not fall below +10˚C.
Even if the MRD10/14 work down to
temperatures as low as +5°C, its capacity
will increase at higher temperatures as
warm air carries more water.
The hydrostat has a margin of error of
approx. +/- 5-10%. At lower temperatures,
the margin of error might increase further.
For maximum dehumidifying power in
a room, it is recommended that the air
supply from outside and from adjoining
rooms is minimized – close doors and
ventilators.
Expect higher dehumidification capacity
during Autumn / Summer because the
outside air is warmer and more humid.
IMPORTANT! - Wood's
dehumidifier must be connected
to an grounded power source.
The power source should be 220V-240V
REMEDY
Check that dehumidifier is connected to electricity and that fuse has not
gone.
Check that the water reservoir is empty and correctly placed in the
dehumidifier.
Remove the water from the container.
Place the water container in the correct position.
Clean the air filter.
Check that air can flow freely though the dehumidifier. Front grid and air
filter should be clean and dehumidifier should stand 20cm from wall.
We recommend using a dehumidifier with a larger capacity.
We recommend using a dehumidifier with a larger capacity.
Reduce ventilation(e.g close windows and shut doors)
50Hz

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mrd14

Table des Matières