Basic Operation
"VOLTAGE CORRECTION" LED: this green LED lights continuously
whenever the UPS is automatically correcting high or low AC voltage
on the utility line without the assistance of battery power. The UPS
will also emit a slight clicking noise. These are normal, automatic
operations of the UPS, no action is required on your part.
"OUTPUT LOAD LEVEL" LED: this multicolored LED indicates the
approximate electrical load of equipment connected to the UPS's AC
outlets. It will turn from green (light load) to yellow (medium load)
to red (overload). If the LED is red (either illuminated continuously
or flashing), clear the overload immediately by unplugging some of
your equipment from the outlets until the LED changes from red to
yellow (or green) and the alarm is no longer sounding. CAUTION!
Any overload that is not corrected by the user immediately may
cause the UPS to shut down and cease supplying output power
in the event of a blackout or brownout.
"BATTERY CHARGE" LED: when the UPS is operating from utility
power, this LED indicates the approximate charge state of the
UPS's internal batteries: red indicates the batteries are beginning to
charge; yellow indicates the batteries are roughly midway through
charging; and green indicates the batteries are fully charged. When
the UPS is operating from battery power during a blackout or severe
brownout, this LED indicates the approximate amount of energy
(ultimately affecting runtime) which the UPS's batteries will provide:
red indicates a low level of energy; yellow indicates a medium level
of energy; and green indicates a high level of energy. Since the
runtime performance of all UPS batteries will gradually deplete over
time, it is recommended that you periodically perform a self-test (see
MUTE/TEST Button description) to determine the energy level of your
UPS batteries BEFORE a blackout or severe brownout occurs. During
a prolonged blackout or severe brownout, you should save files
and shut down your equipment since battery power will eventually
be depleted. When the LED turns red and an alarm sounds
continuously, it indicates the UPS's batteries are nearly out of power
and UPS shut down is imminent.
"BATTERY WARNING" LED: this LED lights red and an alarm sounds
intermittently after you initiate a self test (See "MUTE/TEST" Button
description) to indicate the UPS batteries need to be recharged or
replaced. Allow the UPS to recharge continuously for 12 hours, and
repeat the self-test. If the LED continues to light, contact Tripp Lite
for service. If your UPS requires battery replacement, visit
www.tripplite.com to locate the specific Tripp Lite replacement
battery for your UPS.
7
18-08-322-932245.indb 7
5/3/2019 1:44:54 PM