ACE Instruments AL5500 plus Notice D'utilisation page 10

Alcotest
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
The shown garbage bins mean that batteries must not be
thrown into the household waste.
The signs below the garbage bins are acronyms for the
chemical substances inside the battery:
Hg: Battery
contains Mercury
Cd: Battery
contains Cadmium
Pb: Battery
contains Lead
Technical data*:
Sensor
Accuracy
Detection Range
Warm-up Time
Dimension
Weight
Power Supply
Working Temperature
Storage Temperature
Calibration
*The technical data are subject to change without
prior notice for functional improvements.
Semiconductor sensor
+/- 0.10‰ (per mill) with reference
to 0.50‰ (per mill = default setting
in the EU)
OR +/- 10% with reference to 0.05%
BAC (default setting in the USA)
OR +/- 0.05mg/L with reference to
0.25mg/L (default setting in UK)
0.000 - 4.000‰ (per mill)
OR 0.000 - 0.400% BAC (USA)
OR 0.000 - 2.000mg/L (UK)
Within 30 seconds at 0.5‰ (EU
setting), it may vary depending
on the value of per mill which
was measured in a test shortly
done before
110 x 46 x 20 mm (H x W x D)
89g (batteries included)
2 pieces of 1.5V AA size Alkaline
battery
0°C - 40°C
0°C - 50°C
After approx. every 6 months
(Recommendation)
For a calibration service you can
send the device to ACE Instruments
(see www.ace-instruments.net).