12.4.6
Fine Offset Adjust
The fine adjust should only be performed after both Gain and Offset Adjusts have
been performed.
1) From the TopMenu, select "Others..."
2) From the "Others..." menu, select "Analog In"
3) From the Analog In menu select an input that is configured for PT100 input.
4) Select "Offset fine" from the Analog Input settings menu.
5) Using the + and - buttons, enter a value from -15.5°C to 15.5°C (-27.9°F to 27.9°F) for a
PT100 input or -31°C to 31°C (-55.8°F to 55.8°F) for a TC input. Press the OK button when
finished.
AL2-2PT-ADP 12
T o pMe n u
C l o c k s e t
L ANGUAGE
O t h e r s . . .
O t h e r s
. . .
L i g h t
T i
me
A n a l o g
I
n
P r o g C l e a r
A n a l o g
I n
I 0 1
I 0 2 : PT 1 0 0
I 0 3 : TC
I 0 2
Mo d e
Ca l i b r a t e
O f f s e t
f i n e
I 0 2
O f f s e t
f i n e
0 . 0 ° C
ENG-70