Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools Needed
Tape measure
Phillips screwdriver
Flat-blade screwdriver
Level
Drill
Parts Supplied
Check that all parts are included.
Blower housing assembly with electronic box and intake
assembly
(4) Mounting brackets (front and rear mounting brackets) with
screws
Grease filter
(2) Blower hold down brackets to secure blower to cabinet
Round duct 2-piece telescoping (blower assembly)
Foam strip
(4) Sheet metal screws to secure transition to downdraft
intake and one transition
Parts Needed
For vented installations:
6" (15.2 cm) round metal ducting
Jenn-Air
wall cap:
®
Jenn-Air
6" (15.2 cm) round wall cap with damper
®
(8) Round or pan head wood and sheet metal screws
See the "Assistance or Service" section in your Use and
Care manual to order.
For non-vented installations:
Recirculation Kit part number W10807915 (See the
"Assistance or Service" section in your Use and Care
manual to order.)
a. Recirculation duct housing
b. (4) Mounting screws
c. (2) Charcoal filters
d. Recirculation housing cover
e. (2) Mounting screws – cover
f.
Duct extension
g. (4) Mounting screws – duct extension
For non-vented installations side recirculation only:
1-6" (15.2 cm) round 90 degree elbow and 1-6" (15.2 cm)
round to 3Z\v" x 10" (8.3 cm x 25.4 cm) transition and
1- 3Z\v" x 10" (8.3 cm x 25.4 cm) elbow.
Plywood Pedestal to raise blower mounting. See instruction
detail for non-vented installation.
Check local codes. Check existing electrical supply. See the
"Electrical Requirements" section.
It is recommended that all electrical connections be made by
a licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
When installing the downdraft, use the minimum dimensions
given.

INSTALLATION REQUIREMENTS

Marker or pencil
Pliers
Jigsaw
Caulking
Aluminum duct tape
Use the countertop opening dimensions that are given
with these Installation Instructions. Given dimensions are
minimum clearances and provide 0" (0 cm) clearance.
The model/serial/rating label is located on the front face of
the electrical junction box cover.
A. Model/serial/rating label location
Grounded electrical supply is required. See the "Electrical
Requirements" section.
If cabinet has drawers, drawers will need to be removed
and drawer fronts installed on front of cabinet.
NOTE: The exhaust system is for outside venting. For
non-vented (recirculating) installation, see "For non-vented
(recirculating) installations only" in the "Connect Vent System"
section. Recirculating Kit part number W10807915 is available
from your dealer or an authorized parts distributor.
IMPORTANT: An undercounter built-in oven cannot be installed
under this product.
Electrical Connection Locations
Center of Intake
C
A
B
A. 3 prong grounding type outlet with correct polarity
B. 12" (30.5 cm) from centerline of downdraft intake
C. 18" (45.7) minimum
A
3