1) Confirm that the valve has been
installed properly.
NOTE: The finished wall surface
should be between the min and
max markings on the plaster
guard. See the TSST installation
manual for further information.
2) Remove the plaster guard from
the valve.
3) Measure the distance from the
finished wall to the top of the
trim adapter. Compare that
distance with the table below to
determine which stop to use:
X
Less than 2-1/16"
(53mm)
2-1/16" (53mm)
or more
4) Remove the trim adapter.
Install the proper length
temperature limit stop,
making sure that the align-
ment marks on the valve
body and limiter line up
(roughly at 1 o'clock posi-
tion).
Reinstall the trim adapter.
INSTALLATION PROCEDURE
Use
Long Temperature Limit Stop
1.5" (37.5mm) *
Short Temperature Limit Stop
1" (25mm)
* Pre-installed on valve
Trim Adapter
4
Plaster Guard
Finished Wall
Plaster Guard
Trim Adapter
Alignment
Mark on Stop
Max 95mm (3-3/4")
Min 65mm (2-1/2")
Thermostatic
Valve
Valve
(X)
Finished Wall
Alignment
Mark on Valve