4. Slide the cooktop into the cabinet opening. Verify that the
cooktop is level from side to side and front to rear. (Fig. 3)
Fig. 3
5. Fix the cooktop in the cabinet opening on both left and
right using four self-tapping screws on both left and right
(2 screws each side). (Fig. 4)
Fig. 4
Gas Connection
WARNING
Gas supply pipe must be installed with clearance from
knives contacting or cutting gas lines.
Connect a propane supply line with a ⅜" Flare Female
connection to the cooktop in the upper left rear corner of the
cabinet. (Fig. 5) Tighten the gas line joint to the cooktop using
2 wrenches.
IMPORTANT: Leave adequate space around the gas supply
pipe in case of bend or damage during installation. Make sure
the gas supply pipe cannot contact any moving parts after
installed. Be sure all openings in the cabinet around the gas
line are sealed at time of installation.
Fig. 5
8
CCD-0005608
REV: 10.15.2022
Pressure Check
1. Turn LP gas off to the appliance.
2. Remove the Screw with the sealing gasket from the
pressure test port on the range. (Fig. 6)
Fig. 6
3. Using the rubber tube from the pressure check measuring
device, slide the rubber tube down over the gas pressure
test port. The rubber tube should seal around the pressure
test port on the range.
4. Turn on the LP gas to the appliance.
5. The pressure gauge tester should measure between 10"
WC to 13.8" WC. (Fig. 7)
Fig. 7
6. Turn off the LP gas to the appliance.
7. Remove the rubber tube of the pressure check measuring
device.
8. Replace the screw with the gasket from step 2. Before
replacing the screw, inspect the rubber gasket seal for any
signs of damage. Replace seal if damaged.
9. Tighten the screw to 1.3 Nm to 1.7 Nm.
NOTE: Ensure the product is gas leak checked after the
pressure check test is completed by also testing the pressure
check port screw. If any leaks are detected around the
pressure check port screw and gasket, a new one can be
purchased. Call Furrion support for a replacement.
Electrical Connection
CAUTION
PRODUCT DAMAGE HAZARD
Connect to 12V DC service only.
Connect only to protected circuit fused for not more
than 15 Amps.
DO NOT hi-pot range unless electronic ignition system
has been disconnected.