1. Description

The Booster systems are prepared
for supplying water under pressure
to a number of Ter min als/Satellites
from which the cleaning is carried
out.
The Booster systems are built of
solid materials, mainly stainless
steel.
A typical Booster installation with
Terminals/Satellites is illustrated in
Fig. 1:
Booster (1)
Mixing System (2)
Terminal/Satellite (3)
The systems are available in 3
sizes:
Booster 6 (Fig. 2, wall model)
Single pump system.
Wall or fl oor mounted.
Water capacity: Max. 6 m
Flow controlled - the pump
starts when the water con-
sumption exceeds 3 l/min.
Direct start
1. Pump
2. Check valve
3. Ball valve with union
4. Pressure switch (protection
against dry running). Stops the
pump after 3 sec. if there is not
suffi cient water.
5. Filter
6. Pressure gauge
7. Flow switch
8. Control box
9. Control panel (is placed in the
cabinet on wall model)
O
Push-button. Stops the
system
I
Push-button. Starts the
system
Lamp. Lights up in case of
system fault
10. Thermostat. Stops the pump if
the inlet temperature exceeds
70°C
3
Fig. 1
3
/hour.
9
Fig. 2
2
3
5
4
7
3
1
17453c
8
10