Step 1 : Analysis
Analyses the state of the battery (charge level,
polarity inversion, wrong battery...)
Step 2 : Recovery
Recovering damaged elements after deep and
prolonged discharge.
Step 3 : Test
Sulfated battery test
Step 4 : Desulfation
Battery desulfation algorithm.
Step 5 : Charge
Fast charge at maximum current to reach 80%
charge level.
LFP Lithium charging curve:
1
2
U
I
Analysis
UVP Wake up
Step 1 : Analysis
Analyses the state of the battery (charge level,
polarity inversion, wrong battery...)
Step 2: UVP Wake up
Reactivates batteries in UVP protection (Under
Voltage Protection)
Step 3: Recovery
Recovery algorithm following a deep discharge.
Step 4 : Charge
Maximum current fast charge to reach an 90%
charge level.
Step 5: Absorption
Constant voltage charge to reach a 95% charge
level.

POWER SUPPLY MODES: SHOWROOM / DIAG+

• Setting the mode:
Press the SELECT button for 3 seconds
1
to activate the modification of the mode
settings.
2 Use the arrows to change the value of the
parameter.
Press the SELECT button to accept the value
3
and move to the next parameter.
Power limitation: If the symbol «*» appears next to the current setting (eg «I: 50A *»), this indicates that the
3
4
Recovery
Charge
0%
2%
Step 6: Absorption
Constant voltage charge to reach 100% charge
level.
Step 7: Refresh (only for liquid profile)
The charger supplies an additional current to create
gas that will allow the electrolyte to be mixed and
thus reconditioning the battery cells. During this
phase, the battery may produce some water.
Step 8 : Maintenance/Floating charge
Maintains battery charge level at its maximum.
5
6
Absorption
Test
85%
95%
Step 6 : Test
Charge conservation test.
Step 7 : Supplement
Reduce current charge to reach 100% charge level.
Step 8: Equalization / Balancing
Balancing the battery cells
Step 9: Maintenance/Floating charge
Maintain the battery charge level at its maximum.
1
2
1- Mode name
2- Voltage to be regulated
3- Rated voltage
4- Maximum current
7
8
Equalizing Battery System
Equalization /
Supplement
Balancing
99%
100%
12V
SHOWROOM
U:13.5V
I:50A
9
Maintenance/
Floating charge
3
4
7