Technical Data; Performance Specifications - Graco 333466E Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

F

TECHNICAL DATA

EN
F1
The performance diagram shows fl w rate as a function of back pressure.
Functioning
Point
A
(Maximum fl w rate)
B
(High fl w rate)
C
(Normal conditions)
D
(By pass)
NOTE
NOTE
NOTE
6

PERFORMANCE SPECIFICATIONS

Typical Delivery Configu ation
36
12
16
33
12
17
30
12
19
0
12
20
The curve refers to the following operating condi-
tions:
Fluid: DEF
Temperature: 20° C (68 °F)
Suction conditions: The pipe and the pump position
relative to the fluid level is such that a low pressure
of 0.3 bar (4 psi) is generated at the nominal flow
rate.
Under different suction conditions higher low
pressure values can be created that reduce the flow
rate compared to the same back pressure values. To
obtain the best performance, it is very important to
reduce loss of suction pressure as much as possible
by following these instructions:
• shorten the suction pipe as much as possible
• avoid useless elbows or throttling in the pipes
• keep the suction filter clean
• use a pipe with a diameter equal to, or greater
than, indicated (see Installation).
By-pass pressure is 1.7 bar (24 psi)
The wetted materials used in this device are :
stainless steel, plastic and rubber suitable for AdBlue.
Delivery closed
M0309

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

127643