English
Congratulations on the purchase of the Wigam ELD-H Refrigerant Gas Leak Detector, the most
technologically advanced of its kind. The ELD-H's low power requirements, small size and high sensitivity
combine to create a tool which is easy to handle and ultra effective at locating even the most difficult-to-find
leaks.
Fully SAE J1627 compliant, the ELD-H will detect leaks as small as 0.1 oz/yr (3g/year) in R12, R22, R134a
and other halogen refrigerant systems.
The ELD-H should not be used on systems that contain flammable refrigerants such as Propane, Isobutane,
etc.
TECHNICAL DATA
Dimensions
Weight
Batteries
Battery Life
Sensitivity
Sensor lifetime
Operating temperature
Warm up time
Response time
Reset time
Probe length
7.25" x 2.25" x 1.5" (19 cm x 5.7 cm x 3.8 cm)
7 oz. (190 grams)
2 x 1.5V 'AA' Alkaline Batteries (3 VDC)
40 hours
< 3g/year (0.1 oz/yr)
approx. 30 hours
32 – 122°F (0 – 50°C)
< 2 sec.
instantaneous
instantaneous
12" (30 cm)
1