Daily Maintenance; Brush Replacement - Uline H-8041 Mode D'emploi

Masquer les pouces Voir aussi pour H-8041:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DAILY MAINTENANCE

1.
Use the attached drain hose to empty the dirty
water from the recovery tank. (See Figure 7)
Figure 7
2. Remove lid and check that dirty water tank float is
undamaged, clean and moves freely on pin.
(See Figures 8 and 9)
Figure 8
3. Lift off recovery tank to clean. (See Figure 10)
Figure 10
4. Clean brush and check squeegee is clean and
blades are not damaged. (See Figure 11)
Figure 11
PAGE 2 OF 9
MAINTENANCE
Figure 9
5. Check battery charge. (See Figure 12)
Figure 12
6. To recharge batteries, plug in battery charger using
electrical cord provided with machine. Charge is
complete when the green LED light is on.
(See Figures 13 and 14)
Figure 13
REPLACING THE SQUEEGEE BLADE
1.
Remove the squeegee assembly using the two
black knobs.
2. Remove the squeegee
blade by removing the
screws, wing nuts and
blade retainers.
(See Figure 15)
3. Reuse the same blade
by reversing the edge
in contact with the floor.
The blades should be
reused until all four
edges are worn out
and can be replaced
at once.
4. Align the new (or reversed) blades with the tabs and
screw holes on the squeegee body.
5. Reposition the two blade retainers, and insert the
screws. Attach and tighten the wing nuts.

BRUSH REPLACEMENT

1.
With the underside exposed, remove brush by
rotating clockwise off the center hub.
2. Install new brush by rotating counterclockwise onto
the center hub.