Press the "Up"
or "Down"
the current memorized temperature (in °C or °F as pro-
grammed, see "Temperature unit of measure).
Press the "Up"
or "Down"
displayed value from a minimum of 15 °C to a maximum of 40
°C (59 ÷ 104 °F).
To show the temperature of the water in the tub again, do not
touch any key for about 5 seconds.
As soon as the water temperature set point is reached, the
heater is shut off. It will not be turned back on until the water
temperature drops about 0.5 °C - 1 °F below the set point.
To ensure precise measurement of the water temperature,
the filtering pump comes on every half hour for about 30 sec-
onds (even if no filtering cycles are set), since the temperature
probe is located in the heater pipe.
NOTES
- When the system is turned off, or there is a power outage,
the last set point is stored in memory.
- Operation of the heater is shown on the display by a symbol
displayed steady. If it is flashing, it means that heating has
been suspended to keep from exceeding the maximum per-
mitted consumption. See also the previous note.
CAUTION
Do not use the water at temperatures over
40°C.
I
Maintenance of minimum temperature of water in tub
and anti-freeze protection of the pipes ("Smart Winter").
At regular intervals, the system reads the actual temperature.
If it is below the minimum admissible value (15 °C - 59 °F), the
heater and the filtering pump are automatically activated until the
temperature rises above that value.
"Smart Winter" lets you make use of a special probe to moni-
tor the temperature of the compartment under the tub, which con-
tains the all of the pipes of the plumbing circuit. In extreme con-
ditions, the system may turn on this anti-freeze protection (indi-
cated on the display by the message ICE). The pumps will be
turned on according to the following configurations:
• With limitation of electrical consumption
The pump is turned on at high speed, and turns off after 1
minute. During this cycle the heater is turned off but will be re-
activated later.
• Without limitation of electrical consumption
The operating mode remains the same, except for the heater,
which remains operative.
The pumps are turned on at preset intervals, depending on the
temperature:
key. The display will show
key again to change the
29
- temperature between 12 and 15 ° C (54 - 59 °F):
Every 2 hours
- temperature between 9 and 12 ° C (48 - 54 °F):
every hour
- temperature between 6 and 9 ° C (42 - 48 °F):
every 30 minutes
- temperatures at or below 6 ° C (42 °F):
every 15 minutes
NOTES
- If the temperature of the compartment drops rapidly, the fre-
quency of activation increases.
- If it becomes necessary to turn on the anti-freeze protection
during the filtering or rapid filtering ("Boost") cycles, those cy-
cles will be suspended and they will resume when the anti-
freeze cycle is complete.
- If it is necessary to perform an anti-freeze cycle while a func-
tion activated by the user is in progress, the cycle will be ac-
tivated 15 minutes after the end of the function.
- If this protection is active, the spotlight may still be turned on.
I

WATER FILTERING

The water needs to be filtered to keep it clean, clear and
i
inviting. The pump runs the water through a cartridge filter
in the skimmer
7 (two in Kios Friendly, see the chap-
ter on "Maintenance of cartridge filter"). This operation
takes place based on a cycle during the day (filtering cy-
cle) which repeats every 24 hours.
MaxiJacuzzi is also equipped with a special kind of filtering
("Boost"). This is instantaneous filtering, which differs from the
normal cycle due to its brief, intense duration.
NOTE: the pump has two speeds: a low one used to
circulate and filter the water, and a higher speed to ac-
tivate the hydromassage jets.
If "Performance", the optional external filtering group
(spa-pak), is connected to the spa's electronic control
box, its pump will work at the same time as the spa's
pump, but only when the spa's pump is operating at
low speed. It is activated using the control panel, dur-
ing a filtering cycle, or when the water temperature is
measured.
NOTE: some MaxiJacuzzis are equipped with an o-
zone generator (optional) or a UV light gener-
ator (Clearray™), which helps disinfect and pu-
rify the water. When the filtering cycle is start-
ed, the generator starts automatically, and
shuts off at the end of the cycle.
General Information
The filtration cycle has two phases: