To program the Keypad, follow the procedure described in this paragraph.
Remember that pressing the ENTER key confirms the input values and a move
forward is made to the next step while each pressing of the ESC key cancels the
input values and a step backwards is made (up to exiting the programming
phase).
NOTE - The keypad exits the programming phase one minute after the last
button was pressed.
¾ To set the addresses, use keys C and D to scroll through the available
addresses, or key the address into the Keypad:
¾ to enter addresses greater than 9, key the second digit of the address within 2
seconds of the first;
¾ if you enter an incorrect address, wait at least 1 second before trying again.
On the LCD keypad, the address that has been set is shown by the last two characters
of the top line of the display.
On the LED Keypad, the address set is shown by LEDs 1 to 16:
¾ when an LED lights up, it indicates that the corresponding address has been set;
¾ when an LED flashes, it indicates that the address which has been set is 16 + the
number of the LED.
For example, if LED 9 is lit, it indicates that address no. 9 has been selected; if LED
9 flashes, it indicates that address no. 25 (16 + 9) has been selected.
During all the steps involved in programming, the bottom line of the LCD Keypad
display shows all the keys which can be used at any given time.
PROGRAMMING THE LCD KEYPAD
1) Press and keep pressed the keys 1 and OFF for at least 3 seconds after which
the programming phase starts: the display will show in the first line the name of the
keypad (PREMIUM) and the actual address (for example,1).
2) Programming the ADDRESS - Set the address of the keyboard (from 1 to 32),
then press ENTER to confirm the appearing address and move on to the next step
or press ESC to cancel the change and exit programming.
3) Programming the PROXIMITY READER - Press ON to enable the Proximity
Reader, then set the address of the Proximity Reader (from 1 to 32), then press
ENTER to confirm and move on to the next step or,
press OFF to disable the Proximity Reader, then press ENTER to confirm and move
on to the next step or,
press ESC to cancel the changes and return to the preceding step.
4) Programming the INPUT EXPANDER - Press ON to enable the Input Expander,
then set the address of the Input Expander (from 1 to 32) then press ENTER to
confirm and move on to the step no. 6 or,
press OFF to disable the Input Expander, then press ENTER to confirm and move
on to the next step or,
press ESC to cancel the changes and return to the preceding step.
The zones corresponding to terminals L4, L5 and L6 of the Keypad Input
Expander, although appearing on the application/display, CANNOT be used.
5) Programming the OUTPUT EXPANDER - Press ON to enable the Output
Expander, then then set the address of the Output Expander (from 1 to 16) or use
the keys C and D to scroll the addresses, then press ENTER to confirm and exit
programming or,
press OFF to disable the Output Expander, then press ENTER to confirm and move
on to the next step or,
press ESC to cancel the changes and return to the preceding step.
The outputs corresponding to terminals OC4, OC5 and OC6 of the Keypad Output
Expander, although appearing on the application/display, CANNOT be used.
It is possible to enable ONLY ONE of the two Espanders: either the Input or the
Output Expander. If you do not want to use any Expander, put in the value OFF
for both of them.
6) Programming of the ZONES - Press the keys 1, 2 or 3 to change the functioning
mode, of the corresponding zone, respectively, at terminal T1, T2 or T3, as shown
in the following table, then
press ENTER to confirm and exit from the programming or,
press ESC to cancel the changes and return to step no. 4.
If the Input Expander and the Output Expander have been disabled, it would be
possible to program only the functioning mode relative to terminal T1 and T2.
3URJUDPPLQJ RI =RQHV
#
7KH ]RQH IXQFWLRQV LQ 1RUP DO 0 RGH
7KH ]RQH RSHUDWHV LQ QRUP DO P RGH RU UDWKHU LW HQWHUV DODUP P RGH RQ
WKH EDVLV RI WKH SURJUDP P HG 6HQVLWLYLW\ DQG DV DQ ,QWHUIDFH IRU
$%
6KXWWHU &RQWDFW RU UDWKHU LW HQWHUV DODUP P RGH ZKHQ LW GHWHFWV
NQRFNV LQ WKH VSDFH RI P LQXWHV
The FAST functioning mode (Roller blind) could be entered only with the proce-
dure described in these instructions, and not by software, through the Bentel
Security Suite application (the Roller blind Quality for the Zones related to the
Keypads Input Expander is blocked).
PROGRAMMING THE LED KEYPAD
For programming the LED Keypad, follow the procedure described below.
1) Press and keep pressed the keys 1 and OFF for at least 3 seconds after which
the programming phase starts.
2) Programming the ADDRESS -The lit LED I indicates that the keypad address
is being programmed.
Program the required address for the Keypad (from 1 to 16), then
press ENTER to confirm and move on to the next step or,
press ESC to cancel and exit programming.
3) Programming the PROXIMITY READER - The lit LED a indicates that the
Proximity Reader address is being programmed.
Press ON to enable the Proximity Reader, then program the address which you
would like to assign to the Proximity Reader (from 1 to 32), then
press ENTER to confirm and move on to the next step or,
press OFF to disable the Proximity Reader, then
press ENTER to confirm and move on to the next step or,
press ESC to cancel the changes and return to the preceding step.
4) Programming the INPUT EXPANDER - The lit LED G indicates that the Input
Expanderis being programmed.
Press ON to enable the Input Expander, then program the address which you
would like to assign to the Input Expander (from 1 to 32), then press
ENTER to confirm and move on to the step no. 6 or,
press OFF to disable the Input Expander, then press ENTER to confirm and move
on to the next step or,
press ESC to cancel the changes and return to the preceding step.
The zones corresponding to terminals L4, L5 and L6 of the Keypad Input
Expander, although appearing on the application/display, CANNOT be used.
5) Programming the OUTPUT EXPANDER - The lit LED V indicates that the
Output Expander is being programmed. Press ON to enable the Output Expander,
then program the address which you would like to assign to the Output Expander
(from 1 to 16), then press ENTER to confirm and exit from
programming or,
press OFF to disable the Output Expander, then
press ENTER to confirm and move on to the next step or,
press ESC to cancel the changes and return to the preceding step.
6) Programmazione of the ZONES - The lit LED T, S S S S S , X and P P P P P indicate that the
functioning mode of the zone is being programmed.
LEDs 1, 2 and 3 show the programmed operating mode, respectively for the zones
corresponding to terminals T1, T2 and T3:
¾ LED lit = normal operating mode (NORM);
¾ LED flashing = normal operating mode + interface for roller blinds (FAST).
Press keys 1,2 or 3 to change, respectively, the operating mode of the zones
corresponding to terminals T1, T2 and T3:
Press ENTER to confirm and exit from the programming or,
press ESC to cancel the changes and return to step no. 4.
The FAST functioning mode (Roller blind) could only be input by using the
procedure described in these instructions, and not by software, through the
Bentel Security Suite application (the Roller blind Quality for the Zones related
to the Keypads Input Expander is blocked).