ATTIX 170 / ATTIX 170 E
Class L, M, H with cartridges cleaning
1
Timer
2
Filter cleaning solenoid valve 1
3
Filter cleaning solenoid valve 2
4
Filter cleaning solenoid valve 3
5
Filter cleaning solenoid valve 4
T1 = Filter cleaning time
T2 = Work hold time
T3 = Time between cleaning cycles
Class L with electric filter shaker and automatic
cleaning
1
Power supply
2
Phase sequence relay
3
Vacuum cleaner
4
Electric filter shaker
1
Transformer
2
Voltage signalling (white indicator)
3
Phase sequence indicator (yellow indicator)
1
Stop button
2
Start button
3
Logo controller input
4Filter shaker buttons
1
Vacuum cleaner contactor
2
Filter shaker contactor
3
Logo controller output
I
1
Fuse box
2
Mouth connector
GB
F
Item
Description
H1
White lamp
D
H3
Yellow lamp
KM1
KW 4 24 VAC 1NO Contactor
KM2
KW 3 24 VAC 1NC Contactor
E
PA
Red button
PM
Green button
PS1
Yellow button
Q1
Circuit breaker 9-12,5 A for 8 41593
Q2
Circuit breaker 0.7-1 A
SF1
Phase sequence relay
TR1
Transformer 20 VA 400/24 V
P1
24RC Logo controller
XC1
3P + T Connector
C328
Figure 29
Figure 30
Figure 31
Figure 32
Figure 33
Figure 34
Figure 35
Q.ty
Recommended spare parts
The following is a list of spare parts that should be kept ready
at hand in order to speed up maintenance operations:
■
Main filter
■
HEPA filter
■
Chamber gasket
■
Filter gasket
■
Main filter tightening clamps
■
ABS safety container
■
Dust bags
To order spare parts, please refer to the manufacturer's spare
parts catalogue.
1
1
1
1
1
1
1
1
1
1
1
1
1
14
11/2008