TROUBLESHOOTING

Problem
Cause
Rooftop air
conditioner
Freeze sensor has tripped.
constantly switches
itself off
The rooftop air conditioner is
not set to cooling.
The set temperature is too high.
The evaporator fan is damaged.
Not cooling well
The condenser fan is damaged.
The air intake grilles are
blocked or obstructed.
The blower is defective.
The condensation water
drainage openings are clogged
Water enters the
up.
vehicle
The seals are damaged.
No supply voltage connected.
Rooftop air
The voltage is too low.
conditioner does not
switch on
Fuse blown or circuit protector
tripped.

SPECIFICATIONS

Cooling Capacity (Btu/h)
Dehumidification (pint/h)
Applicable vehicle length (feet)
Refrigerant
Charge (Oz)
Roof top Unit Dimensions (L x W x H) (inch)
Volts/Frequency
Power Watts (Cooling)
Amps (Cooling)
Power Cord Gauge Min. (mm2)
** Product color.
CCD-0005773 Rev: 04-25-22
Remedy
Outer temperature is too low or all air nozzles are closed.
Set the rooftop air conditioner to cooling.
Select a lower temperature.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Remove any leaves and other dirt from the ventilation grilles of the rooftop air conditioner.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Clean the drainage openings for condensation water.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Check the power supply.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this
manual).
Check the electrical fuse of the power supply.
FACR13HESA-**
FACR14SA-**
FACR13HESA-**-AM
FACR14SA-**-AM
13,500
14,500
1.8
2.7
23
26
R410A
R410A
13.9
19.8
347/8 x 275/8 x 135/8
347/8 x 275/8 x 135/8
ELECTRICAL
115V~/60Hz/1Ph
115V~/60Hz/1Ph
1,283
1,620
11.3
14.6
AWG12
AWG12
- 11 -
FACR15SA-**
FACR15HESA-**
FACR15SA-**-AM
FACR15HESA-**-AM
15,500
15,000
3.2
3.0
31
31
R410A
R410A
23.1
20.8
347/8 x 275/8 x 135/8
347/8 x 275/8 x 135/8
115V~/60Hz/1Ph
115V~/60Hz/1Ph
1,720
1,760
15.4
15.6
AWG12
AWG12