Installation; General - Hatco Flav-R-Savor FSD-1 Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour Flav-R-Savor FSD-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

General

Flav-R-Savor
Humidified Holding and Display Cabinets
®
are shipped with most components installed and ready for
operation. The following installation instructions must be
performed before plugging in and operating the cabinet.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where the ambient air temperature is
a minimum of 70°F (21°C).
FIRE HAZARD: Locate unit a minimum of 1" (25 mm) from
combustible walls and materials. If safe distances are not
maintained, discoloration or combustion could occur.
Locate unit at the proper counter height in an area that is
convenient for use. The location should be level to prevent
the unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
The National Sanitation Foundation (NSF) requires that
units over 36" (914 mm) in width or weighing more than
80 lbs. (36 kg) either be sealed to or raised above the
installation surface. If unit cannot be sealed at the point
of use, 4" (102 mm) legs are available to allow for proper
cleaning access below unit.
Transport unit in upright position only. Before moving or
tipping unit, secure all glass surfaces with tape and drain
water from water reservoir. Failure to do so may result in
damage to unit or personal injury.
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces
of the unit, shelves, and any accessories.
• Floor Sheet — The stainless steel floor in all cabinets
is protected during shipping with a sheet of corrugated
cardboard. This protection must be removed prior to
cabinet operation.
• Display Rack — The display rack has packing material
and cardboard attached for protection during shipping.
This protection must be removed prior to cabinet
operation.
• Legs — The cabinets are shipped with four rubber
feet attached to the bottom of the unit. For cabinets
with the optional 4" (102 mm) adjustable legs, see the
OPTIONS AND ACCESSORIES section for installation
instructions.
NOTE: If installing 4" (102 mm) legs, do not remove glass
protection until leg installation is complete.
• Glass Side Panels — The cabinets have tempered glass
side panels that are protected during shipping using
foam sheets along the glass edges and tape to hold the
panels securely. The sheets and tape must be removed
prior to cabinet operation.
Form No. FSDM-0119
NOTE: Any impact to the tempered glass can cause breakage.
To remove a glass panel, grasp the panel firmly from
inside and outside of the cabinet. Lift up and out of the
bottom channel, then carefully lower the glass panel
until it clears the upper channel.
To reinstall, position the glass panel top edge under the
cabinet lip. Raise the panel until it clears the bottom
channel, then carefully lower the panel until it rests in
the bottom channel.
3. Place the unit in the desired location. Two people are
required for this step.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F
(21°C). Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods,
air conditioning ducts, and exterior doors).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
• Make sure all the feet on the bottom of the unit are
positioned securely on the countertop.
Digital
Temperature
Controller
Fill Cup
Access Door
Glass Side
Panel
7

INSTALLATION

POWER ON/OFF
(I/O) switch
Air Heating
System
Components
Display
Rack

Publicité