Operation
Resetting Your Inverter/Charger to Restore AC Power
Your Inverter/Charger may cease supplying AC power or DC charging power in order to protect itself from overload or to protect your electrical
system. To restore normal functioning:
Overload Reset: Switch operating mode switch to "DC OFF" and remove some of the connected electrical load (i.e., turn off some of the AC
devices drawing power which may have caused the overload of the unit). Wait one minute, then switch operating mode switch back to either
"AUTO/REMOTE" or "CHARGE ONLY."
Output Circuit Breaker Reset: If tripped, remove a portion of the load, wait one minute and then press breaker button to reset.

Configuration

Set Configuration DIP Switches
Using a small tool, set the Configuration DIP Switches (located on the front panel, see diagram) to optimize Inverter/Charger operation
depending on your application. Refer to the appropriate section to review the instructions for your specific model.
Group A DIP Switches (All Models)
Using a small tool, configure your Inverter/Charger by setting the four Group A DIP Switches (located on the front panel of your unit; see
diagram) as follows:
Select Battery Type—REQUIRED
A1
CAUTION: The Battery Type DIP Switch setting must match the type of batteries you connect, or your batteries may be
degraded or damaged over an extended period of time. See "Battery Selection" section for more information.
Battery Type
AGM/Gel Cell (Sealed) Battery
Wet Cell (Vented) Battery
Select Charger Enable/Inhibit
A2
Switch is preset to ENABLE, which permits continuous battery charging. If you are connecting your unit to batteries
with a separate charger, you may set this switch to INHIBIT to disable its built-in charger to prevent overcharging.
Battery Type
Inhibit
Enable
Select Low AC Input Voltage Point for Switching to Battery—
A4 A3
OPTIONAL*
Voltage and Level
120V Models
230V Models
A 105V
201V
B 95V
182V
C 85V
163V
D 75V
144V
* Most of your connected appliances and equipment will perform adequately when your Inverter/Charger's Low AC Voltage Input Point (DIP Switch #3 and #4 of
Group A) are set to Level B (95V for 120V Models/182V for 230V Models). However, if the unit frequently switches to battery power due to momentary low line
voltage swings that would have little effect on equipment operation, you may wish to adjust this setting. By decreasing the Low AC Voltage Input Point, you will
reduce the number of times that your unit switches to battery due to voltage swings.
B4
B3
B2
B1
Group B Dip Switches
Switch Position
Up
Down (factory setting)
Switch Position
Up
Down (factory setting)
Switch Position
A4 Up & A3 Up
A4 Up & A3 Down
A4 Down & A3 Up
A4 Down & A3 Down (factory setting)
INPUT C/B 10A
5
A4
A3
A2
A1
OUTPUT C/B 12A
Group A Dip Switches
A4
A3
A2
A4
A3
A2
A4
A3
A4
A3
A2
A1
Level A
A4
A3
A2
A1
A4
A3
Level B
A1
A1
INHIBIT
ENABLE
A2
A1
Level C
A2
A1
Level D