Technical Information; Technical Data; Safety Devices - Nussbaum POWER LIFT HF 3000 Manuel D'exploitation

Masquer les pouces Voir aussi pour POWER LIFT HF 3000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3

Technical information

3.1

Technical data

Load carrying capacity HF 3000 = 3000 kg
Loading a lifting arm
Load distribution
Lift / lowering time
Standard operating
voltage
Motor capacity
Motor speed
Hydraulic pump
Lifting, lowering pressure
(dyne)
Pressure relief valve
Oil volume
Noise level L
PA
on-site connection
Optional energy set
OPI-POWER LIFT HF 3000-4000-HYMAX HF 3000-4000-V1.3-DE-EN-FR-ES-IT
HF 3500 = 3500 kg
HF 4000 = 4000 kg
A single load from only
one lifting arm may not
happen
HF 3000/HF 3500:
max. 2:3 or 3:2 mm or
against the drive-in di-
rection
HF 4000:
max. 1:3 or 3:1 mm or
against the drive-in di-
rection
approx. 33 sec. / approx.
28 sec. with 3300 kg
3 ~/N+PE,400 volt, 50 Hz
2,2 kW
2800 rpm
2,5 cm³
230 bar / 130 bar
(at 3300 kg)
approx. 250 bar
approx. 7 litres (HLP32)
≤ 70 dB
3~/N+PE, 400V, 50 Hz
with 16 Amp slow blow
fuse according to VDI
Regulations
Pneumatic connection
> for compressed air
6 – 10 bar
Socket: 220 V/50 hz
3.2

Safety devices

• Over-pressure valve
Hydraulic system fuse against over-pressure.
• Check valve
Secure the vehicle against unauthorised lower-
ing.
• Main switch with curtain lock device
Fuse to prevent unauthorised use.
• Command / downstream system with latch
Secure against unauthorised lowering of the lift.
• Deadman controls
Lift movement stops when the operating lever is
released.
• Foot bumpers on the lifting arms
Secure against shear and crushing points in the
foot area.
• Lifting arm block
Secures the lifting arm against horizontal move-
ment in a lifted condition.
69

Publicité

Table des Matières
loading