© Kirami Oy, Finland
Fastening the stove
External CULT stoves are supplied separately and the stove's package includes model-specific
instructions and supplies for attaching them. Breezy tub do not have handles, as the stove will be
placed so close to the ground that it is easier to support from underneath. On an even surface,
there should be approx. 20 mm of space for the support below the stove. However, the proper
height of the support should always be checked at the installation site. Any drink trays / cover
plates can be attached to the stove's handles with screws supplied with the stove. Ensure the
water-tightness and fastening to the tub. A model-specific drink stand / protective panelling series
attached to the stove are available.
Grates
Cult stoves come with a cradle fireplace grate where a single wire tray grate
is installed. An air iron plate is placed on the top shelf to direct the circulation
of air in the upper part of the firebox. The plate in the upper part of the
stove must not be pushed too far so that it prevents the exhaust of the
smoke. It is prohibited to use the stove without these parts. Note that these
parts wear down over time and get bent and their form will change in use.
You can purchase new ones as spare parts when needed.
Chimney
Be careful, the edges of the chimney are very sharp. Use protective
gloves! The chimney is delivered in a separate box and it consists of four
parts (picture on right) and it needs to be assembled. Remove the
protective film from the thermal protection and place the assembled
chimney to the chimney outlet of the stove.
The first use
The water circulation of the stove shall be rinsed by letting plenty of water in from the pipe above,
so that any metal chips from grinding come out. Collect any trash by swiping it off the bottom of the
tub. When you fill the tub, check the fastening pipes of the stove for any leakages.
USE

OPERATIONAL ADVICE

If there is a filter connected to the hot tub. It shall be cleaned and dried if possible whenever the
hot tub is emptied.
No manual dosing of chemicals shall be performed while bathers are present in the hot tub.
It is recommended that the means of access (steps) for hot tub should be away from the chimney to
avoid the user touching the chimney by accident.
Water is to be stirred before measurement to mix the hot surface water with the cooler water
below to prevent false readings. This is to be performed before measuring the temperature and
entering the hot tub the water. Safety check of temperature with bather's elbow is also
recommended just before going into the water.