Installation Instruction Supplement - Luminaire with Ambient Integrated Sensor
Cooper Lighting Solutions Integrated Sensor System Series Features - SVPD1, SVPD2, SVPD3, SVP3
SVPD1 Coverage Pattern (not to scale)
Top View
C L
Coverage
4m
[12 ft.]
0m
[0 ft.]
4m
[12 ft.]
Major Motion
SVPD2 Coverage Pattern (not to scale)
Top View
9.1m
C L
[30 ft.]
6.1m
[20 ft.]
4.5m
[15 ft.]
3m
[10 ft.]
1.5m
[5 ft.]
0
1.5m
[5 ft.]
3m
[10 ft.]
4.5m
[15 ft.]
6.1m
[20 ft.]
9.1m
[30 ft.]
SVPD3, SVP3 Coverage Pattern (not to scale)
Side View
0
6.1m
[20 ft.]
9.1m
[30 ft.]
12.2m
9.1m
6.1m
[40 ft.]
[30 ft.]
[20 ft.]
Notes:
The coverage pattern shown above depicts the area below the luminaire where the integrated sensor system can detect occupancy.
(1)
Spacing between fixtures should not exceed the coverage pattern of the sensor.
(2)
Exceeding these spacing/height guidelines will result in reduced integrated sensor performance.
(4)
Default Settings - SVPD1, SVPD2, SVPD3, SVP3
Occupancy Detection
Default Occupancy Time Out
Occupancy Sensitivity
Energy Saver Scene
Fade Up Time
Fade Down Time
Default Daylight Harvesting Level
Default Unoccupied Light Level
Side View
3.3m
[10 ft.]
0m
[0 ft.]
4m
0m
4m
[0 ft.]
[12 ft.]
[12 ft.]
Recomended Mounting Height 8–12 ft.
Side View
0
2.4m
[8 ft.]
6.1m
[20 ft.]
3m
0
3m
6.1m
[10 ft.]
[10 ft.]
[20 ft.]
Auto-on, Active
20 minutes
High
100 % - Occupied Scene
32% per second using "Raise"
24% per second using "Lower"
Consult luminaire specification sheet(s)
(1)
Off
Installation instructions Supplement - Luminaire with Ambient Integrated Sensor
ADF14295 V01 www.cooperlighting.com
3m
3m
6.1m
0
[10 ft.]
[10 ft.]
[20 ft.]
4.5m
1.5m
1.5m
4.5m
[15 ft.]
[5 ft.]
[5 ft.]
[15 ft.]
9.1m
12.2m
[30 ft.]
[40 ft.]
Mounting height should not exceed coverage shown.
(3)