Note: Before installation with electrical
control systems, check that equipment
to be used is of sufficient rated capacity
to accept amperage draw of motor. Low
voltage will cause motor to overheat.
Maintenance
The system shall be periodically
sanitized using the following procedure:
1. Fill the tank with a solution of
house hold bleach and
potable water – 1 ml (.03 oz.)
bleach/1 l (32 oz.) water.
2. Open all faucets and run until water
flowing smells of bleach.
3. Close all fauces.
4. Drain solution from tank.
5. Refill tank with potable water.
6. Open all faucets and run until
bleach has been purged.
Wiring table
Black
Green/yellow
Other electrical devices, eg switch,
circuit breaker, must be installed
between the pump and the positive (+)
lead on the battery (on the red wire).
10
Max 0.2 m
Terminal
fuse
Pump
Wiring dimensions
(based on 3% voltage drop)
WPS 2.9
Wire size
1,5 mm²
2,5 mm²
4,0 mm²
6,0 mm²
WPS 3.5
Wire size
2,5 mm²
4,0 mm²
6,0 mm²
10 mm²
WPS 4.0
Wire size
Red
2,5 mm²
4,0 mm²
6,0 mm²
10 mm²
WPS 5.2
Wire size
2,5 mm²
4,0 mm²
6,0 mm²
10 mm²
16 mm²
* The wire length is the total distance from the
©battery to the pump and back to the battery.
It is recommended to use a relay with a light
wire from main cable to switch to shorten the
main leaders.
Max wire
lenght* in m
12V 24V
# 16 AWG
5
# 14 AWG
8
# 12 AWG
13
# 10 AWG
19
Max wire
lenght* in m
12V 24V
# 14 AWG
5
# 12 AWG
8
# 10 AWG
13
# 6 AWG
19
Max wire
lenght* in m
12V 24V
# 14 AWG
7
# 12 AWG
11
# 10 AWG
16
# 6 AWG
27 122
Max wire
lenght* in m
12V 24V
# 14 AWG
5
# 12 AWG
8
# 10 AWG
12
# 6 AWG
20
# 4 AWG
31 138
Original instructions
21
34
55
82
21
34
52
82
30
49
73
22
34
52
86