7.2
Display
Settings
Time
Week day
Language
Domestic hot water
Setpoint
Hysteresis
Lower value
Min. temperature
Time programs
HP block
Time
Day
Thermal disinfection
Time
Setpoint
Day
Solar
Switch-on diff.
Switch-off diff.
Max. tank temperature
Max. collector temperature
EN-8
All manuals and user guides at all-guides.com
Description
Sets the current time
Sets the current week day
Sets the desired language
Sets the desired domestic hot water setpoint
Sets the switching hysteresis
Sets the domestic hot water lower value
Sets the minimum domestic hot water temperature, which should also
not be undershot for the duration of a programmed shut-off time.
Sets the start and end time for a heat pump block
Sets the week day / block of days on which the heat pump block should
be activated
Sets the start time for thermal disinfection
Sets the set temperature for thermal disinfection. The heating element
is additionally used for this function
*(to achieve the increased temperatures, observe Chapt. 2.1 on page
3)
Sets the day on which thermal disinfection should be activated
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched on
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched off
Sets the maximum cylinder temperature that is permissible when solar
gain is available
Sets the maximum permissible temperature on the collector
Setting range
00:00:00
Mo
....
Su
DE
EN
FR
25
...45 °C...
60
2
...3 K...
10
0
5 K
10
15
...25 °C...
40
00:00 -
00:00
Mo - Su (day)
Mo - Fr (block)
Sa - Su (Block)
Mo - Su (block)
00:00:00
60
...65 °C...
(75)*
Mo - Su (day)
Mo - Fr (block)
Sa - Su (Block)
Mo - Su (block)
6
...8...
10
2
...4...
6
60
...65 °C...
85
125
...130 °C...
135