L
S
E V E L
W A R N I N G
!
Never perform service while the platform is elevated without first blocking the elevating assembly.
DO NOT stand in the elevating assembly area while deploying or storing the brace.
The Level Sensor Is located on the chassis between the scissor sections and is covered with a protective
metal box. To verify the sensor is working properly there are two LED's under the sensor; green indicates
the sensor is ON (has power), red indicates the sensor is LEVEL.
T
ESTING THE
1. Place machine on firm level surface.
2. Use the Chassis Controls to raise the
platform to approximately 2,1 m (7 ft.).
3. Install the scissor brace (see "Blocking
The Elevating Assembly" on page 14).
4. Remove the Level Sensor electrical box
cover near the front of machine.
5. Push the Level Sensor off of level.
6. The alarm should sound, and the red
LED should turn OFF.
• If the alarm does not sound, take the
machine out of service until the Level
Sensor has been adjusted or
repaired.
7. Replace the Level Sensor electrical box
cover.
8. Store the scissor brace and lower the
Platform.
114100-020 X26 Ultra Narrow - Operator Manual
All manuals and user guides at all-guides.com
E N S O R
L
S
EVEL
ENSOR
!
Maintenance
Figure 10: Level Sensor
Page 15