Maintenance
SAFETY VALVE (NOT SUPPLIED)
The water heater's safety valve sometimes releases a little
water after hot water usage. This is because the cold water,
which enters the water heater, expands when heated causing
the pressure to rise and the safety valve to open.
The function of the safety valves must be regularly checked,
about four times a year, to prevent clogging.
To inspect the valve, open the safety valve manually and
check that water flows through the overflow pipe. If this does
not happen then the safety valve is defective and must be
replaced.
EMPTYING
Water heater
Draining is performed through the siphon (using hose) in the
cold water connection.
Charge coil
Draining is performed through the siphon (using hose) in the
docking connection, return to heat pump.
SERVICE
For service, contact the installer. Serial number (18 digits) and
installation date should always be stated.
Only original replacement parts supplied may be used.
PIPE CONNECTIONS
XL3 Connection, cold water
XL4 Connection, hot water
XL8 Docking connection, supply line (from heat pump)
XL9 Docking connection, return line (to heat pump)
HVAC COMPONENTS
UA1 Submerged tube for hot water sensor (display) BT7
UA2 Submerged tube for hot water sensor (control) BT6