DLA-G150CLU&CLE_Eng.book Page 60 Thursday, February 21, 2002 2:39 PM
Replacing the Light-Source Lamp
I Be sure that the power cord is unplugged from the wall outlet.
1
Remove the lamp-replacement opening
cover by loosening screws.
Loosen the two screws with a flat-end screwdriver.
Note
• The screws are fitted so that they do not come off the lamp-
replacement opening cover.
2
Loosen the screws, raise the handle,
and pull out the light-source lamp.
Loosen the two screws with a flat-end screwdriver.
Note
• The screws are fitted so that they do not come off the light-
source lamp.
60
DLA-G150CLU / LCT1123-001B / ENGLISH
Screw
Lamp-replacement
opening cover
Be careful not to damage
the claw.
Screw
Light-source lamp
Handle
(To be continued on the next page)