Airflow Direction Control - Senville SENL/12HD/MI Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATING INSTRUCTIONS

Airflow direction control

SET TEMPERATURE
AUTO
COOL
DRY
HEAT
TEMP
ON/OFF
MODE
SWING
SLEEP
RESET LOCK
AIR
DIRECTION
Range
Lever
Range
NOTE:
on the indoor units. Please refer to the <<REMOTE
CONTROLLER ILLUSTRATION>> supplied with the unit
to operate the unit properly if your remote controller is
( C)
different with the following instructions.
FAN
Adjust the air flow direction properly, otherwise it might
HIGH
MED
cause discomfort or cause uneven room temperatures.
LOW
Adjust the horizontal louver using the remote controller.
Adjust the vertical louver manually.
To set the vertical air flow(Up--Down) direction
FAN SPEED
Perform this function while the unit is in operation. Keep
TIMER ON
pressing the AIR DIRECTION button on the remote
controller to move the louver to the desired direction. The
TIMER OFF
readjusting angle of the horizontal louver is 6 for each
LED
DISPLAY TURBO
press.
To set the horizontal air flow direction (left - right)
Adjust the vertical louver manually using the lever on the
left or right side of the vertical louver arm (Depending on
model). Take care not to catch fingers on the fan,
horizontal louver or to damage vertical louvers. When the
air conditioner is in operational and the horizontal louver
is in a specific position, move the lever at left (or right,
depending on model) end of the air outlet to the desired
position.
To automatically swing the air flow direction (up - down)
Perform this function while the air conditioner is in operation.
Keep pressing the AIR DIRECTION button without
releasing for more than 2 seconds or press the SWING
button on the remote controller, the horizontal louver
will swing up and down automatically.
To stop the function, press the SWING button again.
!
CAUTION
The SWING and AIR DIRECITON button will be disabled when the air
conditioner is not in operation(including when the TIMER ON is set).
Do not operate the air conditioner for long periods with the air flow
direction set downward in cooling or dry mode. Otherwise,
condensation may occur on the surface of the horizontal
louver causing moisture to drop on to the floor or on furnishings.
Do not move the horizontal louver manually. Always use the SWING
or AIR DIRECTION button.
When the air conditioner is started immediately after it was stopped,
the horizontal louver might not move for approximately 10 seconds.
Open angle of the horizontal louver should not be set too small, as
COOLING or HEATING performance may be impaired due to too
restricted air flow area. Do not operate unit with horizontal louver in
closed position.
When the air conditioner is connected to power (initial power), the
horizontal louver may generate a sound for 10 seconds, this is a
normal operation.
The remote controller is different types depending
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Senl/18hd/mo

Table des Matières