NEWLIFT UCM-A3 Manuel D'utilisation page 29

Table des Matières

Publicité

Annex to the EU Type Examination Certificate
It is not mandatory that the specified types of "contactors for brake/valves" as well as
"zone magnet switches" be used. The type can be selected based on the reaction and de-
tection times of the "contactors for brake/valves" as well as the "zone magnet switches". If
types other than those specified above are used, verification of the reaction and detection
times is to be provided.
Shown on the following pages are the wiring diagram for rope-operated passenger and
freight lifts (figure 3), the wiring diagram for hydraulically operated lift systems with shutoff
valve as braking element (figure 4) as well as the wiring diagram for hydraulically operated
lift systems with redundant lowering valves as braking elements (figure 5).
Figure 3: Wiring diagram for rope-operated passenger and freight lifts
Figure 4: Wiring diagram for hydraulically operated lift systems with shutoff valve
as braking element
Manuel d'utilisation de UCM-A3
No. EU-ESD 023 of 2016-10-04
29

Publicité

Table des Matières
loading

Produits Connexes pour NEWLIFT UCM-A3

Table des Matières