Friedrich Thru-the-Wall Serie Guide D'installation Et De Fonctionnement page 17

Masquer les pouces Voir aussi pour Thru-the-Wall Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROCEDURE C CONTINUED
To achieve rearward slope for unit draining,
7
remove the backing from the 11
strips and attach them as shown below in Fig.
23. The higher portion of shim is to be placed
in front of the rib on the base of wall sleeve.
1" high
6"
8
Remove the metal rear grille and replace it with
the plastic rear grille to improve unit energy
efficiency. The plastic grille reduces the
amount of hot air discharge that recirculates
through the unit.
9
Install the new unit into the wall sleeve
Assemble trim as described in Step 6,
10
Procedure A.
13 /
" shim
16
3
/
" High
4
FIG. 22
Shim (2EA)
6"
FIG. 23
Plastic rear grille
Steel rear grille
FIG. 24
• Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people are
needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
• When handling the air conditioner, be careful to avoid
cuts from sharp metal fins on front and rear coils.
• Make sure air conditioner does not fall during
removal.
• If unit does not operate after installation check, to be
sure the circuit interrupter has not been tripped. Refer
to the Troubleshooting guide for reset procedure.
17
CAUTION

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Us08Us10Us12

Table des Matières