Technical Data - Steinbach CPS 40-2 Notice D'utilisation

Masquer les pouces Voir aussi pour CPS 40-2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
Troubleshooting
Problem
Air bubbles escape from the
injection nozzle or the pump emits
unusual noises.
The pump is not running.
If the problem cannot be solved, contact the customer service listed on the last page.

Technical data

Model:
CPS 40-2
Item number:
040955
Pump function principle:
not self-priming
Prefilter:
- - - - -
Timer:
- - - - -
Battery for timer:
- - - - -
Power supply:
220-240 V~, 50 Hz
Output:
max. 200 W
**** Emission sound level comparable to a large household appliance
22
Possible cause
The pump is sucking in air.
The water level in the pool is too
low.
The suction line is out of place
or clogged.
The pump has no power.
The external timer is set.
The pump is defective.
Flow rate:
Delivery head:
Pool volume (water
content):
Water temperature:
Connection diameter:
Safety class:
Insulation class:
Sound pressure level ****:<70 dB(A)
Remedy
Check all hoses and gaskets for leaks.
Retighten the hose clamps.
Check the water level in the pool and fill
with more water if necessary until the
pool water covers the suction line
connection approx. 2.5 - 5cm (1 to 2 in).
Raise the water level in the pool.
Clean the pressure line.
Connect the pump's power plug to the
power supply. Check whether the fuse
has tripped.
Check the running times on the external
timer.
Contact customer service.
max. 4,500 l/h (36.3 GPM)
max. 6.5 m (21 ft.)
max. 19,000 l (10,000 gal)
max. 35 °C (95 °F)
Ø 32/38 mm
IPX5
F

Publicité

Table des Matières
loading

Table des Matières