Faults / Trouble-
Shooting (for Users)
ATTENTION!
Work on the hot-water heat pump is to be performed by qualified
personnel only! Observe accident prevention regulations!
The heat pump will not run!
Please check whether
the plug is plugged in
the operating switch is switched on
the socket has voltage
air inlet temperature or ambient temperature is ≥ 12.5 °C
heat pump has not been switched off via the temperature
controller
the hot water temperature has already reached (or exceeds)
60 °C
The heat pump switches off prematurely (set
temperature has not been reached)
Please check whether
ducts have been bent or their openings have been sealed,
or whether any air filters are heavily contaminated (clogged)
Condensate cannot flow away (there is water in or
under the device)
Please check whether
the seal valve in the condensed water hose is contaminated
or clogged - clean it, if necessary; the valve can be easily re-
moved and replaced
ventilation is extremely reduced
(bent duct / clogged air filter)
If the above questions cannot help you eliminate these faults,
please contact your technician or customer services.
E-10
All manuals and user guides at all-guides.com
10 Shut-Down
Tasks to be carried out:
11 Environmental
During start-up and shut-down of the hot-water heat pump, all
environmental requirements regarding recovery, recycling and
disposal of materials and components should be observed, in ac-
cordance with DIN EN 378.
Disconnect hot-water heat pump from power source.
Completely shut off water circuit (hot water, cold water and
circulation pipe) and drain hot water cylinder.
Requirements