12 Device Information
1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices and
heating components
2.2
Installation location
3
Performance data
3.1
Operating temperature limits:
1
Heating water flow / return flow
Air
3.2
Heat output / COP at
3.3
Sound power level
3.4
Sound pressure level
at a distance of 10 m (air outlet side)
3.5
Pool water flow with an internal pressure differential of
3.6
Refrigerant; total filling weight
3.7
Lubricant; total filling weight
3.8
El. output of defrost heater
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
5.4
Nominal current
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing
7.3
Performance levels
1. See operating limits diagram
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. E.g. A20 / W24 have the following meaning: external air temperature 20°C and swimming
pool flow temperature 24 °C.
3. See CE declaration of conformity
4. Continuous operation of the filter pump must be ensured on-site and the heat pump controller must be ready for operation.
www.dimplex.de
All manuals and user guides at all-guides.com
°C / °C
°C
2
A20 / W24
kW / -
dB(A)
dB(A)
m³/h / Pa
type / kg
type / litres
kW
H x W x L cm
Inch
kg
V / A
2
A15 / W32
kW
A
A15 / W32 / cos M
A / ---
4
LAS 10MT
LAS 15MT
IP 24
IP 24
Outdoors
Outdoors
Up to 40 / above 10
Up to 40 / above 10
-10 to +35
-10 to +35
12.1 / 4.2
16.6 / 4.7
70
70
45
45
1.6 / 7200
2.0 / 12000
R407C / 1.5
R407C / 1.6
FV68S / 1.7
FV68S / 1.7
1.8
2.4
86 x 127 x 67
86 x 127 x 67
G 1'' external
G 1'' external
147
155
230 / 20
230 / 25
3.3
4.0
33
43
17.0 / 0.8
21.0 / 0.8
3
3
Automatic
Automatic
Electrical
Electrical
Yes (heated)
Yes (heated)
Yes
Yes
1
1
12
LAS 22TT
IP 24
Outdoors
Up to 40 / above 10
-10 to +35
22.3 / 5.1
71
46
2.5 / 8000
R407C / 2.5
FV68S / 1.7
3.0
86 x 127 x 67
G 1 1/2'' external
162
400 / 16
5.1
25
10.0 / 0.8
3
Automatic
Electrical
Yes (heated)
Yes
1
E-9