Call (INCALL)
The "INCALL" function can be connected to any output ("OUT1"=relay, "OUT2"= transistor).
This function can be used in two modes:
"Toggle" mode: The output is switched in case of a call
"Time" mode: The output is switched for a time that can be selected
Only the phone numbers previously recorded can use this function.
Simply call the "GX107" and let the phone ring a few times to be sure. Ensure
that the phone number from which the "GX107" is called is not unknown
(number withheld) and that it was saved in the right format in the "GX107".
Otherwise, the "GX107" will ignore the call and not switch an output.
INCALL settings:
SET INCALL <OUT1/OUT2> <Time for Switching On> #1513
Example:
SET INCALL OUT1 23 #1513
This command causes Output1 to switch on for 23 seconds in case of a call.
Time can be set from 1 to 43200 seconds (12 hours).
If time is set to "0", the "INCALL" "toggle" mode is selected. That means that the
first time the "GX107" is called, the output will be switched on, the second time
it will be switched off, etc.
Reset to Default Settings
Send the following command to reset the default settings (OUT1, time = 0):
RESET INCALL #1513
Test Settings
To test the desired settings, use the command:
TEST INCALL #1513