MANY COMMON PROBLEMS CAN BE SOLVED EASILY BY UTILIZING THE
CHART BELOW. FOR MORE SERIOUS OR PERSISTENT PROBLEMS, CONTACT
A D
WALT SERVICE CENTER OR CALL 1-(800)-4-D
e
WARNING: To reduce the risk of serious personal injury, ALWAYS disconnect air
from tool and engage trigger lock, before all repairs.
SYMPTOM
Air leak near top of
tool or in trigger area
Tool does nothing or
operates sluggishly
Air leak near
bottom of tool
Tool jams frequently
Other
Height (inch/mm)
Width (inch/mm)
Length (inch/mm)
Weight (lbs/kg)
Recommended Operating Pressure 70-120 psi (4.8 to 8.3 bar)
Air Consumption per 100 cycles
Loading capacity
TROUBLESHOOTING GUIDE
PROBLEMS
Loose screws.
Worn or damaged
o-rings or seals.
Inadequate air supply.
Inadequate lubrication.
Worn or damaged
o-rings or seals.
Loose screws.
Worn or damaged
o-rings or bumper.
Incorrect fasteners.
Damaged fasteners.
Bent collation wire.
Canister or nose screws loose Tighten screws.
Canister is dirty.
Driver tip is worn or damaged. Install Driver Maintenance Kit.
TOOL SPECIFICATIONS
14 - ENG
WALT (1-800-433-9258).
e
SOLUTIONS
Tighten screws.
Install Overhaul Kit.
Verify adequate air supply.
Put 5 or 7 drops of
oil into air inlet.
Install Overhaul Kit.
Tighten screws.
Install Overhaul Kit.
Verify approved fasteners
of correct size and 15°
collation angle.
Replace with undamaged
fasteners.
Clean magazine.
Contact a D
Warranty Service Center
DWFP12658
10.5/ 266
4.3/ 110
10.3/ 262
4.91/ 2.23
4.13 CFM
120 nails
WALT Authorized
e