Configuration of the «EXPERT» curve settings:
Once the
charging curve is activated, it is possible to config-
EXPERT
ure the curve settings (type IU
• Ucharge: Charging voltage adjustable between 12 and 16 V
(charging level 7)
• Icharge: Adjustable charging current from 10 A to 200 A for a
battery capacity of 100 Ah (level 6).
• Urecovery: Recovery voltage adjustable up to 30 V. If OFF is
entered, the recovery function is inactive (charging level 2 and 4)
• Ufloating: Adjustable floating voltage, dependent on the entered
rated U value. If OFF is entered, the floating function is inactive
(charging level 9).
• T recovery: maximum time for recovery of the cells in short-circuit,
adjustable between 1 and 24 hours (charging level 2).
• T refresh: Duration of the refresh phase - adjustable between 1 and
12 hours. If OFF is entered, the refresh function is inactive (charging
level 8)
• T desulfat: adjustable, maximum time of desulphation phase be-
tween 1 and 24 hours (charging level 8).
• T ch_max: maximum charging time (charging level 7 and 6).
• T ch_min: minimum charging time (charging level 7 and 6).
• Urefresh: maximum voltage during a refresh period (charging
level 8).
• OCP (overload protection): adjustable, maximum percentage of
the battery capacity prior to protective switch-off (charging level 8).
When charging a still installed battery, a too high
or
Urecovery
Urefresh
electronics. In this case, these parameters should be not
be set with a value greater than 15 V.
To save and activate the new settings, select
f
and select
.
save
Yes
Press
, to exit the settings menu.
Mode
f
24
All manuals and user guides at all-guides.com
I
U):
0
0
CAUTION!
voltage may damage the vehicle
ADVANCED MENU
,
Advanced Menu
ON
ADVANCED MENU
Change bat.:
OFF
OFF
ON
ADVANCED MENU
Power Supply: OFF
OFF
ON
ADVANCED MENU
expert curve:
OFF
OFF
OFF
ON
12.0V
EXPERT CURVE
12.1V
...
Ucharge:
14.3V
16.0V
10A/100Ah
EXPERT CURVE
11A/100Ah
...
Ichrg:
20A/100Ah
200A/100Ah
OFF
Uch
EXPERT CURVE
...
Urecovery:
OFF
15.9V
16.0V
OFF
12.0V
EXPERT CURVE
12.1V
OFF
...
Uch
1h
EXPERT CURVE
2h
...
T recovery:
5h
24h
1h
EXPERT CURVE
2h
...
T desulfat:
12h
24h
1h
EXPERT CURVE
2h
...
Tch_max:
16h
36h
0h
EXPERT CURVE
1h
...
Tch_min:
0h
Tch_max
OFF
1h
EXPERT CURVE
2h
T refresh:
5h
...
12h
Uch
EXPERT CURVE
...
15.9V
U refresh:
16.0V
16.0V
100%
EXPERT CURVE
...
245%
OCP:
200%
250%
Yes
ADVANCED MENU
Save?
No
No
RETURN
24