12
12 Device Information
1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Cooling, flow
Brine (heat source, heating)
Brine (heat sink, cooling)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow) at B0 / W35
2
3.3
Heat output / COP
6
3.4
Cooling capacity / COP
3.5
Sound power level
3.6
Sound pressure level at a distance of 1 m
3.7
Heating water flow with an internal pressure differential of m³/h / Pa
3.8
Brine throughput with an internal pressure differential (heat source) of m³/h / Pa
3.9
Flow rate of additional heat exchanger with an internal pressure differential m³/h / Pa
3.10 Refrigerant; total filling weight
3.11 Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Device connections for hot water
4.5
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption B0 W35
5.3
Starting current with soft starter
Nominal current B0 W35 / cos ϕ
5.4
5.5
max. power consumption of compressor protection
(per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. See output curves
2. The coefficients of performance for parallel hot water preparation are also achieved via additional heat exchangers.
3. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
4. Operation with 2 compressors
5. Operation with 1 compressor
6. Considerably higher coefficients of performance are achieved by means of cooling operation and waste heat recovery via additional heat exchangers.
7. Note that additional space is required for pipe connections, operation and maintenance.
8. See CE declaration of conformity
9. The heat circulating pump and the heat pump controller must always be ready for operation.
E-8
All manuals and user guides at all-guides.com
1
°C
°C
°C
°C
K
3
at B-5 / W55
kW / ---
kW / ---
3
at B0 / W55
kW / ---
kW / ---
3
at B0 / W35
kW / ---
kW / ---
3
at B20 / W10
kW / ---
3
at B20 / W7
kW / ---
3
at B20 / W18
kW / ---
kW / ---
3
at B10 / W7
kW / ---
3
at B10 / W18
kW / ---
kW / ---
dB(A)
db(A)
type / kg
type / litres
7
H x W x L mm
Inch
Inch
Inch
kg
V / A
3 4
kW
A
4
A / ---
W
9
SI 30TER+
Reversible with additional heat exchanger
IP 21
Indoors
Up to 55±1
+7 to +20
-5 to +25
+5 to +30
Monoethylene glycol
25%
4
22,0 / 2,0
5
11,1 / 2,1
24,9 / 2,2
4
12,8 / 2,3
5
4
28,6 / 3,8
15,2 / 4,2
5
35,3 / 5,3
4
5
18,2 / 6,1
4
44,6 / 6,2
23,6 / 7,5
5
5
21,0 / 8,6
4
46,7 / 7,4
25,4 / 9,5
5
4,7 / 2200
6,7 / 5300
4,0 / 20000
R404A / 8,1
Polyolester / 3,7
1660 x 1000 x 775
G 1 1/2" internal/external
G 2" internal/external
G 1" internal/external
400 / 20
7,53
13,59 / 0,8
Yes
Internal
5
62
46
385
26
70
8
2