DSM 800RC
15kW
Maintenance
Carrier
14 mm
Belts:
Check double toothed belt
(visual check)
Dust protection:
Suction ring
Additional weights Locking:
Mini indexing plunger
Wheels Locking:
Pressure bolt
6
Maintenance plan
1x/Day 1x/Week Notes
X
Check for wear and the 4 bolts with Ø14, if they are smaller
than Ø12 the carriers must be replaced.
At elevated
The double toothed belt must be replaced by qualified or
grinding
trained personnel.
work: 200h
At normal
grinding
work:
350h
X
Before starting work check for wear or tear.
X
Before starting work check function.
X
Before starting work check function.
Visual check
2021 - 02