3. Then store the device and its accessories in a dry and frost-free place (≥ +5 °C) without direct
sunlight.
Troubleshooting
Fault description
1H+1.5H blink and a signal sounds
1.5H+2H blink and a signal sounds
1H+2H blink and a signal sounds
The cable is twisted or tangled.
The device cannot reach all spots.
Cause
The pump is overloaded.
The drive motor is overloaded.
The device is out of the water.
The cable was not completely
detached.
The cable in the water is too long.
The device becomes stuck on the
drain grate.
The control unit was wrongly
positioned.
The water circulation of the pool is
switched on.
The cable is too short.
Remedy
Stop the device and check if the
wheel is blocked by a foreign object.
Check the drive belt.
Stop the device, immerse it in water
and start the device again.
Switch off the device, disconnect the
cable and untangle it.
Pull the excess cable length out of
the water. The cable in the water
should only be long enough so that
the device can reach all spots in the
pool.
Switch off the filter system of the
pool.
Position the control unit so that the
device can easily access all spots.
Switch off the filter system of the
pool.
Let a sufficient length of cable into
the pool so that the device can
reach all spots in the pool. Observe
the minimum distance of the control
unit to the pool.